Lennox SLP99UHV furnace: filter size

Our script found these filter sizes in the Lennox SLP99UHV source document's filter table: 16x25x1, 20x25x1, 24x25x1. This page is pending human review, so check the source excerpt on the page to see which size applies to your cabinet and return.

Auto-extracted · review pending Filter sizes auto-extracted from the manufacturer document.

Filter sizes by cabinet / model

Sizes / part numbers found in the source table
16 X 25 X 1
20 X 25 X 1
24 X 25 X 1

Extracted by script from the linked document. Read the excerpt to see which size applies to which cabinet or return.

Measuring a furnace air filter's edge with a tape measure
Illustration only. Not this manufacturer's part.

Replacement interval

General guidance (not from this manual): check monthly and replace 1-in. filters every 1–3 months, or follow the filter maker's guidance and your owner's manual.

Before you buy

Pull the old filter and read the size printed on its frame. Nominal sizes are rounded up: a 15.5 x 24.5 in. filter is sold as 16 x 25.

Buy

Match the size or part number printed on your current filter.

MERV notes

Your furnace manual lists the filter's dimensions, not its MERV rating. Higher-MERV filters restrict more air. Manufacturers such as Carrier recommend keeping the clean-filter pressure drop under 0.2 in. w.c. (ideally under 0.1). Lennox warns that an over-restrictive filter can trip the high limit in winter and freeze the coil in summer. If you want MERV 11–13, a 4-in. media cabinet is the usual route. Ask an HVAC tech to check static pressure. Nominal sizes are rounded: a filter labeled 16 x 25 x 1 actually measures about 15.5 x 24.5 x 0.75.

Where this data came from

Manufacturer document for Lennox SLP99UHV
Last checked 2026-10-23. Manufacturers revise documents. If your unit's label disagrees, trust the label.

Excerpt from the source

                                                                                                      TABLE 1
 4 - Route auxiliary drain line so that water draining from
                                                                                   Furnace                       Filter Size
      this outlet will be easily noticed by the homeowner.
                                                                                 Cabinet Width        Side Return         Bottom Return
 5-  If necessary, run the condensate line into a
      condensate pump to meet drain line slope                                      17-1/2”         16 X 25 X 1 (1)      16 X 25 X 1 (1)
      requirements. The pump must be rated for use                                    21”           16 X 25 X 1 (1)      20 X 25 X 1 (1)
      with condensing furnaces. Protect the condensate
      discharge line from the pump to the outside to avoid                          24-1/2”         16 X 25 X 1 (2)      24 X 25 X 1 (1)
      freezing.
                                                                             Duct System
 6 - 
      Continue with exhaust, condensate and intake
      piping installation according to instructions.                        Use industry-approved standards to size and install the
                                                                            supply and return air duct system. This will result in a qui-
        INTAKE PIPE                      *GAS CONNECTION                    et and low-static system that has uniform air distribution.
    EXHAUST PIPE                                                            See below for proper duct installation.
   *Gas connector may be
   used for Canadian                                                                  SUPPLY
                                                                                        AIR                                   Install self tapping screws
                                                                                                                                to seal any potential air
   able by local authority                                                                                                                leaks
   having jurisdiction.

FAQ

What size filter does the Lennox SLP99UHV use?

Our script found these filter sizes in the Lennox SLP99UHV source document's filter table: 16x25x1, 20x25x1, 24x25x1. This page is pending human review, so check the source excerpt on the page to see which size applies to your cabinet and return. 16 X 25 X 1; 20 X 25 X 1; 24 X 25 X 1.

How often should I replace the Lennox SLP99UHV filter?

General guidance (not from this manual): check monthly and replace 1-in. filters every 1–3 months, or follow the filter maker's guidance and your owner's manual.

Why doesn't my filter measure exactly 16 x 25?

Filter sizes are nominal (rounded). A filter sold as 16 x 25 x 1 actually measures about 15.5 x 24.5 x 0.75 in. Buy by the nominal size printed on the frame.

Where does this information come from?

Manufacturer document for Lennox SLP99UHV (https://www.lennox.com/dA/e5e74d387e/507999-02c.pdf), last checked 2026-10-23.