Home › Furnace filters › ML180UHE(K)

Lennox ML180UHE(K) furnace: filter size

Our script found these filter sizes in the Lennox ML180UHE(K) source document's filter table: 14x25x1, 16x25x1, 20x25x1, 24x25x1. This page is pending human review, so check the source excerpt on the page to see which size applies to your cabinet and return.

Auto-extracted · review pending Filter sizes auto-extracted from the manufacturer document.

Filter sizes by cabinet / model

Sizes / part numbers found in the source table
14 X 25 X 1
16 X 25 X 1
20 x 25 x 1
24 x 25 x 1

Extracted by script from the linked document. Read the excerpt to see which size applies to which cabinet or return.

Measuring a furnace air filter's edge with a tape measure
Illustration only. Not this manufacturer's part.

Replacement interval

General guidance (not from this manual): check monthly and replace 1-in. filters every 1–3 months, or follow the filter maker's guidance and your owner's manual.

Before you buy

Pull the old filter and read the size printed on its frame. Nominal sizes are rounded up: a 15.5 x 24.5 in. filter is sold as 16 x 25.

Buy

Match the size or part number printed on your current filter.

MERV notes

Your furnace manual lists the filter's dimensions, not its MERV rating. Higher-MERV filters restrict more air. Manufacturers such as Carrier recommend keeping the clean-filter pressure drop under 0.2 in. w.c. (ideally under 0.1). Lennox warns that an over-restrictive filter can trip the high limit in winter and freeze the coil in summer. If you want MERV 11–13, a 4-in. media cabinet is the usual route. Ask an HVAC tech to check static pressure. Nominal sizes are rounded: a filter labeled 16 x 25 x 1 actually measures about 15.5 x 24.5 x 0.75.

Where this data came from

Manufacturer document for Lennox ML180UHE(K)
Last checked 2026-10-23. Manufacturers revise documents. If your unit's label disagrees, trust the label.

Excerpt from the source

                         ENTRY                    VENT
                                                  PIPE         vided high-velocity filter is required for the unit to operate
                                                               properly. TABLE 1 lists recommended filter sizes. A filter
                                                               must be in place any time the unit is operating.
                                                                                         TABLE 1
                                                                    Furnace Cabinet                 Filter Size
                                                                         Width          Side Return          Bottom Return
          SERVICE PLATFORM                                            A - 14-1/2”      16 X 25 X 1 (1)      14 X 25 X 1 (1)
                                                                      B - 17-1/2”      16 X 25 X 1 (1)      16 X 25 X 1 (1)
                          FIGURE 13                                     C - 21”        16 X 25 X 1 (1)       20 x 25 x 1 (1)
                                                                      D - 24-1/2”      16 X 25 X 1 (2)       24 x 25 x 1 (1)
                        CAUTION
If this unit is being installed in a space serviced by an                             IMPORTANT
exhaust fan, power exhaust fan, or other device which           If a high efficiency filter is being installed as part of this
may create a negative pressure in the space, take care          system to ensure better indoor air quality, the filter must
when sizing the inlet air opening. The inlet air opening        be properly sized. High efficiency filters have a higher
must be sized to accommodate the maximum volume                 static pressure drop than standard efficiency glass/foam
of exhausted air as well as the maximum volume of               filters. If the pressure drop is too great, system capacity
combustion air required for all gas appliances serviced         and performance may be reduced. The pressure drop
by this space.                                                  may also cause the limit to trip more frequently during
                                                                the winter and the indoor coil to freeze in the summer,
                        WARNING                                 resulting in an increase in the number of service calls.
                                   

FAQ

What size filter does the Lennox ML180UHE(K) use?

Our script found these filter sizes in the Lennox ML180UHE(K) source document's filter table: 14x25x1, 16x25x1, 20x25x1, 24x25x1. This page is pending human review, so check the source excerpt on the page to see which size applies to your cabinet and return. 14 X 25 X 1; 16 X 25 X 1; 20 x 25 x 1; 24 x 25 x 1.

How often should I replace the Lennox ML180UHE(K) filter?

General guidance (not from this manual): check monthly and replace 1-in. filters every 1–3 months, or follow the filter maker's guidance and your owner's manual.

Why doesn't my filter measure exactly 16 x 25?

Filter sizes are nominal (rounded). A filter sold as 16 x 25 x 1 actually measures about 15.5 x 24.5 x 0.75 in. Buy by the nominal size printed on the frame.

Where does this information come from?