Daikin DM80SN / DC80SN filter sizes: 10 x 20, 14 x 20, 14 x 24, 14 x 25, 16 x 25, 20 x 25 and 24 x 24, as listed in the Daikin source document's filter table. Which size fits depends on your cabinet and return. This page is pending human review, so check the source excerpt below.

Auto-extracted · review pending Filter sizes auto-extracted from the manufacturer document.

Last checked against the manufacturer document:

Filter sizes by cabinet / model

Sizes found in the source table
10 x 20
14 x 20
14 x 24
14 x 25
16 x 25
20 x 25
24 x 24

Extracted by script from the linked document. Read the excerpt to see which size applies to which cabinet or return.

Close-up of a pleated furnace air filter
Illustration only. Not this manufacturer's part.

Replacement interval

General guidance (not from this manual): check monthly and replace 1-in. filters every 1–3 months, or follow the filter maker's guidance and your owner's manual.

Before you buy

Pull the old filter and read the size printed on its frame. Nominal sizes are rounded up: a 15.5 x 24.5 in. filter is sold as 16 x 25.

Buy

Match the size or part number printed on your current filter.

As an Amazon Associate I earn from qualifying purchases.

MERV notes

Your furnace manual lists the filter's dimensions, not its MERV rating. Higher-MERV filters restrict more air. Manufacturers such as Carrier recommend keeping the clean-filter pressure drop under 0.2 in. w.c. (ideally under 0.1). Lennox warns that an over-restrictive filter can trip the high limit in winter and freeze the coil in summer. If you want MERV 11–13, a 4-in. media cabinet is the usual route. Ask an HVAC tech to check static pressure. Nominal sizes are rounded: a filter labeled 16 x 25 x 1 actually measures about 15.5 x 24.5 x 0.75.

Related models

Where this data came from

Manufacturer document for Daikin DM80SN / DC80SN
Last checked 2026-10-28. Manufacturers revise documents. If your unit's label disagrees, trust the label.

Excerpt from the source

DM80SN Minimum Filter Sizes
                                 DM80SN          DM80SN            DM80SN          DM80SN               DM80SN                     DM80SN                       DM80SN
             Model #
                                  0403A*          0603A*            0604B*          0804B*               0805C*                     1005C*                       1205D*
                                   (1) 16 x 25 (Side) or                                               (1) 16 x 25           (2) 16 x 25 (Side) or        (2) 16 x 25 (Side) or
    Filter Size (in²)                                           (1) 16 x 25 (Side or Bottom)
                                   (1) 14 x 24 (Bottom)                                            (Side or Bottom) ¹        (1) 20 x 25 (Bottom)         (1) 24 x 24 (Bottom)
¹Use 2 - 16 x 25 filters on side returns or 1 - 20 x 25 filter on bottom return if furnace is connected to a cooling unit over 4 tons nominal capacity.
Note: Other size filters of equal or greater surface area may be used; filters may also be centrally located.
DC80SN Minimum Filter Sizes
                                           DC80SN                             DC80SN                              DC80SN                                DC80SN
             Model #
                                           0403A*                             0603A*                               0804B*                                1005C*
                                                                                                               (2) 14 x 20 or                        (2) 14 x 20 or
    Filter Size (in²)                      (2) 10 x 20 or (1) 14 x 25 (Top Return)
                                                                                                          (1) 16 x 25 (Top Return)              (1) 20 x 25 (Top Return)
Note: Other size filters of equal or greater surface area may be used; filters may also be centrally located.
                                  Our continuing commitment to quality products may mean a change in specifications without notice.
                                     ©2021                                            • Houston, Texas • Printed in the USA

FAQ

What size filter does the Daikin DM80SN / DC80SN use?

Daikin DM80SN / DC80SN filter sizes: 10 x 20, 14 x 20, 14 x 24, 14 x 25, 16 x 25, 20 x 25 and 24 x 24, as listed in the Daikin source document's filter table. Which size fits depends on your cabinet and return. This page is pending human review, so check the source excerpt below. 10 x 20; 14 x 20; 14 x 24; 14 x 25; 16 x 25; 20 x 25; 24 x 24.

How often should I replace the Daikin DM80SN / DC80SN filter?

General guidance (not from this manual): check monthly and replace 1-in. filters every 1–3 months, or follow the filter maker's guidance and your owner's manual.

Why doesn't my filter measure exactly 16 x 25?

Filter sizes are nominal (rounded). A filter sold as 16 x 25 x 1 actually measures about 15.5 x 24.5 x 0.75 in. Buy by the nominal size printed on the frame.

Does the Daikin DM80SN / DC80SN use more than one filter size?

Yes. The source table lists 7 sizes: 10 x 20, 14 x 20, 14 x 24, 14 x 25, 16 x 25, 20 x 25 and 24 x 24. Which one applies depends on your cabinet and return; check the excerpt (pending human review).

Where does this information come from?

Manufacturer document for Daikin DM80SN / DC80SN (https://cdn.daikincloud.io/PIM/Assets/Documents/SS-DM80SN.pdf), last checked 2026-10-28.