Daikin DR97MC modulating gas furnace: filter size

The Daikin DR97MC modulating gas furnace uses one of 2 filter sizes, depending on cabinet width (or model) and return location: 16x25, 20x25 (per the Daikin document cited on this page). The page's table shows which size applies to each cabinet and return.

Verified from manufacturer doc 97% AFUE upflow/horizontal modulating furnace

Filter sizes by cabinet / model

ModelFilter size(s)
DR97MC0603BN(1) 16 x 25 (side or bottom)
DR97MC0803BN(1) 16 x 25 (side or bottom)
DR97MC0804CN(1) 16 x 25 (side or bottom)
DR97MC1005CN(1) 20 x 25 (bottom) or (2) 16 x 25 (side)
DR97MC1205DN(1) 20 x 25 (bottom) or (2) 16 x 25 (side)

Downflow DD97MC models use different, top-return sizes. Check the same spec sheet.

Measuring a furnace air filter's edge with a tape measure
Illustration only. Not this manufacturer's part.

Replacement interval

General guidance (not from this manual): check monthly and replace 1-in. filters every 1–3 months, or follow the filter maker's guidance and your owner's manual.

Before you buy

Pull the old filter and read the size printed on its frame. Nominal sizes are rounded up: a 15.5 x 24.5 in. filter is sold as 16 x 25.

Buy

Match the size or part number printed on your current filter.

MERV notes

Your furnace manual lists the filter's dimensions, not its MERV rating. Higher-MERV filters restrict more air. Manufacturers such as Carrier recommend keeping the clean-filter pressure drop under 0.2 in. w.c. (ideally under 0.1). Lennox warns that an over-restrictive filter can trip the high limit in winter and freeze the coil in summer. If you want MERV 11–13, a 4-in. media cabinet is the usual route. Ask an HVAC tech to check static pressure. Nominal sizes are rounded: a filter labeled 16 x 25 x 1 actually measures about 15.5 x 24.5 x 0.75.

Where this data came from

DR97MC/DD97MC specification sheet, Product Specifications – Filter Size
Last checked 2026-10-21. Manufacturers revise documents. If your unit's label disagrees, trust the label.

FAQ

What size filter does the Daikin DR97MC modulating gas furnace use?

The Daikin DR97MC modulating gas furnace uses one of 2 filter sizes, depending on cabinet width (or model) and return location: 16x25, 20x25 (per the Daikin document cited on this page). The page's table shows which size applies to each cabinet and return. DR97MC0603BN – (1) 16 x 25 (side or bottom); DR97MC0803BN – (1) 16 x 25 (side or bottom); DR97MC0804CN – (1) 16 x 25 (side or bottom); DR97MC1005CN – (1) 20 x 25 (bottom) or (2) 16 x 25 (side); DR97MC1205DN – (1) 20 x 25 (bottom) or (2) 16 x 25 (side).

How often should I replace the Daikin DR97MC modulating gas furnace filter?

General guidance (not from this manual): check monthly and replace 1-in. filters every 1–3 months, or follow the filter maker's guidance and your owner's manual.

Why doesn't my filter measure exactly 16 x 25?

Filter sizes are nominal (rounded). A filter sold as 16 x 25 x 1 actually measures about 15.5 x 24.5 x 0.75 in. Buy by the nominal size printed on the frame.

Where does this information come from?

DR97MC/DD97MC specification sheet, Product Specifications – Filter Size (https://daikincomfort.com/docs/default-source/dd97mc/ss-dr97mc_dd97mc-r32.pdf), last checked 2026-10-21.