Home › Furnace filters › EL196UHE

Lennox EL196UHE furnace: filter size

Lennox EL196UHE filter sizes: 16 x 25 x 1 and 20 x 25 x 1, as listed in the Lennox source document's filter table. Which size fits depends on your cabinet and return. This page is pending human review, so check the source excerpt below.

Auto-extracted · review pending Filter sizes auto-extracted from the manufacturer document.

Last checked against the manufacturer document:

Filter sizes by cabinet / model

Sizes found in the source table
16 x 25 x 1
20 x 25 x 1

Extracted by script from the linked document. Read the excerpt to see which size applies to which cabinet or return.

Close-up of a pleated furnace air filter
Illustration only. Not this manufacturer's part.

Replacement interval

General guidance (not from this manual): check monthly and replace 1-in. filters every 1–3 months, or follow the filter maker's guidance and your owner's manual.

Before you buy

Pull the old filter and read the size printed on its frame. Nominal sizes are rounded up: a 15.5 x 24.5 in. filter is sold as 16 x 25.

MERV notes

Your furnace manual lists the filter's dimensions, not its MERV rating. Higher-MERV filters restrict more air. Manufacturers such as Carrier recommend keeping the clean-filter pressure drop under 0.2 in. w.c. (ideally under 0.1). Lennox warns that an over-restrictive filter can trip the high limit in winter and freeze the coil in summer. If you want MERV 11–13, a 4-in. media cabinet is the usual route. Ask an HVAC tech to check static pressure. Nominal sizes are rounded: a filter labeled 16 x 25 x 1 actually measures about 15.5 x 24.5 x 0.75.

Related models

Where this data came from

Manufacturer document for Lennox EL196UHE
Last checked 2026-11-06. Manufacturers revise documents. If your unit's label disagrees, trust the label.

Excerpt from the source

  5 - If necessary, run the condensate line into a condensate                                 TABLE 1
      pump to meet drain line slope requirements. The
                                                                           Furnace                        Filter Size
      pump must be rated for use with condensing
      furnaces. Protect the condensate discharge line                    Cabinet Width        Side Return          Bottom Return
      from the pump to the outside to avoid freezing.                       17-1/2”          16 X 25 X 1 (1)       16 X 25 X 1 (1)
  6 - Continue with exhaust, condensate and intake piping                    21”            16 X 25 X 1 (1)       20 X 25 X 1 (1)
      installation according to instructions.
                                                                     Duct System
       INTAKE PIPE                *GAS CONNECTION
                                                                    Use industry-approved standards to size and install the
   EXHAUST PIPE
                                                                    supply and return air duct system. “Figure 20” shows the
                                                                    correct supply and return duct installation. Refer to ACCA
  *Gas connector may be                                             Manual D. This will result in a quiet and low-static system
  used for Canadian
                                                                    that has uniform air distribution.
  able by local authority
  having jurisdiction.                                              NOTE - This furnace is not certified for operation in heat-
                                                                    ing mode (indoor blower operating at selected heating
                                                                    speed) with an external static pressure which exceeds 0.5
                                                                    inches w.c. Operation at these conditions may result in
                                                                    improper limit operation.
                                                                    Supply Air Plenum
                                                     RAISED
                       SERVICE PLATFORM             PLATFORM        If the furnace is installed without a cooling coil, a remov-

FAQ

What size filter does the Lennox EL196UHE use?

Lennox EL196UHE filter sizes: 16 x 25 x 1 and 20 x 25 x 1, as listed in the Lennox source document's filter table. Which size fits depends on your cabinet and return. This page is pending human review, so check the source excerpt below. 16 x 25 x 1; 20 x 25 x 1.

How often should I replace the Lennox EL196UHE filter?

General guidance (not from this manual): check monthly and replace 1-in. filters every 1–3 months, or follow the filter maker's guidance and your owner's manual.

Why doesn't my filter measure exactly 16 x 25?

Filter sizes are nominal (rounded). A filter sold as 16 x 25 x 1 actually measures about 15.5 x 24.5 x 0.75 in. Buy by the nominal size printed on the frame.

How thick is the Lennox EL196UHE filter?

Every size found in the source table is 1 in. thick: 16 x 25 x 1 and 20 x 25 x 1. Pending human review; check the excerpt.

Where does this information come from?

Manufacturer document for Lennox EL196UHE (https://www.lennox.com/dA/77ba4690a5/507764-06g.pdf), last checked 2026-11-06.