Goodman GMSS96 / GCSS96 furnace: filter size

Our script found these filter sizes in the Goodman GMSS96 / GCSS96 source document's filter table: 14x25, 16x25. This page is pending human review, so check the source excerpt on the page to see which size applies to your cabinet and return.

Auto-extracted · review pending Filter sizes auto-extracted from the manufacturer document.

Filter sizes by cabinet / model

Sizes found in the source table
14 x 25
16 x 25

Extracted by script from the linked document. Read the excerpt to see which size applies to which cabinet or return.

Measuring a furnace air filter's edge with a tape measure
Illustration only. Not this manufacturer's part.

Replacement interval

General guidance (not from this manual): check monthly and replace 1-in. filters every 1–3 months, or follow the filter maker's guidance and your owner's manual.

Before you buy

Pull the old filter and read the size printed on its frame. Nominal sizes are rounded up: a 15.5 x 24.5 in. filter is sold as 16 x 25.

Buy

Match the size or part number printed on your current filter.

MERV notes

Your furnace manual lists the filter's dimensions, not its MERV rating. Higher-MERV filters restrict more air. Manufacturers such as Carrier recommend keeping the clean-filter pressure drop under 0.2 in. w.c. (ideally under 0.1). Lennox warns that an over-restrictive filter can trip the high limit in winter and freeze the coil in summer. If you want MERV 11–13, a 4-in. media cabinet is the usual route. Ask an HVAC tech to check static pressure. Nominal sizes are rounded: a filter labeled 16 x 25 x 1 actually measures about 15.5 x 24.5 x 0.75.

Where this data came from

Manufacturer document for Goodman GMSS96 / GCSS96
Last checked 2026-10-25. Manufacturers revise documents. If your unit's label disagrees, trust the label.

Excerpt from the source

                                                                            (1) 16 x 25        (1) 16 x 25         (1) 16 x 25   (1) 16 x 25
                                                           (side) or                                                                             (bottom)         (bottom)          tom)
    Filter Size (in²) (Qty)                                                   (side or           (side or            (side or      (side or
                                                         (1) 14 x 25                                                                           or (2) 16 x 25   or (2) 16 x 25 or( 2) 16 x 25
                                                                             bottom)            bottom)             bottom)       bottom)
                                                          (bottom)                                                                                 (side)           (side)         (side)
    Electrical Data
    Min. Circuit Ampacity⁴                                   9.3                9.6                9.6                12.8          11.7           13.7            13.7            13.7
    Max. Overcurrent Device (amps)⁵                          15                 15                  15                 15           15              15              15                 15
    Shipping Weight (lbs)                                   106                 111                114                116           139            140              142            154
¹      Natural Gas BTU/h
²      DOE AFUE based upon Isolated Combustion System (ICS)
³      Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required).
       Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run
       and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements
       and must be 2" or 3" diameter PVC.
⁴      Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined
       in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
⁵      Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size.
       May use fuses or HACR-type circuit breakers of the same size as noted.
Notes
• All furnaces are manufactured for use on 115 VAC

FAQ

What size filter does the Goodman GMSS96 / GCSS96 use?

Our script found these filter sizes in the Goodman GMSS96 / GCSS96 source document's filter table: 14x25, 16x25. This page is pending human review, so check the source excerpt on the page to see which size applies to your cabinet and return. 14 x 25; 16 x 25.

How often should I replace the Goodman GMSS96 / GCSS96 filter?

General guidance (not from this manual): check monthly and replace 1-in. filters every 1–3 months, or follow the filter maker's guidance and your owner's manual.

Why doesn't my filter measure exactly 16 x 25?

Filter sizes are nominal (rounded). A filter sold as 16 x 25 x 1 actually measures about 15.5 x 24.5 x 0.75 in. Buy by the nominal size printed on the frame.

Where does this information come from?

Manufacturer document for Goodman GMSS96 / GCSS96 (https://cdn.daikincloud.io/PIM/Assets/Documents/SS-GMSS96.pdf), last checked 2026-10-25.