Home › Furnace filters › 58TP0B / 58TP1B

Carrier 58TP0B / 58TP1B furnace: filter size

Carrier 58TP0B / 58TP1B filter sizes: 14 x 25 x 3/4, 16 x 25 x 3/4, 20 x 25 x 3/4 and 24 x 25 x 3/4, as listed in the Carrier source document's filter table. Which size fits depends on your cabinet and return. This page is pending human review, so check the source excerpt below.

Auto-extracted · review pending Filter sizes auto-extracted from the manufacturer document.

Last checked against the manufacturer document:

Filter sizes by cabinet / model

Sizes found in the source table
14 x 25 x 3/4
16 x 25 x 3/4
20 x 25 x 3/4
24 x 25 x 3/4

Extracted by script from the linked document. Read the excerpt to see which size applies to which cabinet or return.

Close-up of a pleated furnace air filter
Illustration only. Not this manufacturer's part.

Replacement interval

General guidance (not from this manual): check monthly and replace 1-in. filters every 1–3 months, or follow the filter maker's guidance and your owner's manual.

Before you buy

Pull the old filter and read the size printed on its frame. Nominal sizes are rounded up: a 15.5 x 24.5 in. filter is sold as 16 x 25.

MERV notes

Your furnace manual lists the filter's dimensions, not its MERV rating. Higher-MERV filters restrict more air. Manufacturers such as Carrier recommend keeping the clean-filter pressure drop under 0.2 in. w.c. (ideally under 0.1). Lennox warns that an over-restrictive filter can trip the high limit in winter and freeze the coil in summer. If you want MERV 11–13, a 4-in. media cabinet is the usual route. Ask an HVAC tech to check static pressure. Nominal sizes are rounded: a filter labeled 16 x 25 x 1 actually measures about 15.5 x 24.5 x 0.75.

Related models

Where this data came from

Manufacturer document for Carrier 58TP0B / 58TP1B
Last checked 2026-10-29. Manufacturers revise documents. If your unit's label disagrees, trust the label.

Excerpt from the source

 7. Replace filter cabinet door.                                                       Failure to follow this warning could result in personal injury or death.
 8. Turn on electrical supply to furnace.                                              Blower access door switch opens 115-V power to control. No
             Table 19 – Filter Size Information - In. (mm)                             component operation can occur unless switch is closed. Caution must
                                   FILTER SIZE                                         be taken when manually closing this switch for service purposes.
  FURNACE                                                           FILTER
CASING WIDTH               SIDE                 BOTTOM               TYPE
                          RETURN                RETURN                                 Clean blower motor and wheel as follows:
                       16 X 25 X 3/4          14 X 25 X 3/4
                                                                                        1. Turn off electrical supply to furnace.
   14-1/2 (368)                                                    Washable*            2. Remove outer door.
                     (406 X 635 X 19)       (356 X 635 X 19)
                       16 X 25 X 3/4          16 X 25 X 3/4                             3. For downflow or horizontal furnaces having vent pipes within the
   17-1/2 (445)                                                    Washable*
                     (406 X 635 X 19)       (406 X 635 X 19)                                furnace that pass in front of the blower access door:
                       16 X 25 X 3/4          20 X 25 X 3/4                                 a. Disconnect vent connector from furnace vent elbow.
     21 (533)                                                      Washable*                b. Disconnect and remove short piece of vent pipe from within
                     (406 X 635 X 19)       (508 X 635 X 19)
                                                                                               furnace.
                       16 X 25 X 3/4          24 X 25 X 3/4
     24 (610)                                                      Washable*            4. Remove screws from blower access door and remove blower access
                     (406 X 635 X 19)       (610 X 635 X 19)
                                                                                            door.
* Recommended
Media Cabinet Filt

FAQ

What size filter does the Carrier 58TP0B / 58TP1B use?

Carrier 58TP0B / 58TP1B filter sizes: 14 x 25 x 3/4, 16 x 25 x 3/4, 20 x 25 x 3/4 and 24 x 25 x 3/4, as listed in the Carrier source document's filter table. Which size fits depends on your cabinet and return. This page is pending human review, so check the source excerpt below. 14 x 25 x 3/4; 16 x 25 x 3/4; 20 x 25 x 3/4; 24 x 25 x 3/4.

How often should I replace the Carrier 58TP0B / 58TP1B filter?

General guidance (not from this manual): check monthly and replace 1-in. filters every 1–3 months, or follow the filter maker's guidance and your owner's manual.

Why doesn't my filter measure exactly 16 x 25?

Filter sizes are nominal (rounded). A filter sold as 16 x 25 x 1 actually measures about 15.5 x 24.5 x 0.75 in. Buy by the nominal size printed on the frame.

How thick is the Carrier 58TP0B / 58TP1B filter?

Every size found in the source table is 3/4 in. thick: 14 x 25 x 3/4, 16 x 25 x 3/4, 20 x 25 x 3/4 and 24 x 25 x 3/4. Pending human review; check the excerpt.

Where does this information come from?

Manufacturer document for Carrier 58TP0B / 58TP1B (https://www.shareddocs.com/hvac/docs/1009/Public/04/58TP0B-01SI.pdf), last checked 2026-10-29.