Home › Furnace filters › 58TN0B / 58TN1B

Carrier 58TN0B / 58TN1B furnace: filter size

Carrier 58TN0B / 58TN1B filter sizes: 14 x 25 x 3/4, 16 x 25 x 3/4, 20 x 25 x 3/4 and 24 x 25 x 3/4, as listed in the Carrier source document's filter table. Which size fits depends on your cabinet and return. This page is pending human review, so check the source excerpt below.

Auto-extracted · review pending Filter sizes auto-extracted from the manufacturer document.

Last checked against the manufacturer document:

Filter sizes by cabinet / model

Sizes found in the source table
14 x 25 x 3/4
16 x 25 x 3/4
20 x 25 x 3/4
24 x 25 x 3/4

Extracted by script from the linked document. Read the excerpt to see which size applies to which cabinet or return.

Close-up of a pleated furnace air filter
Illustration only. Not this manufacturer's part.

Replacement interval

General guidance (not from this manual): check monthly and replace 1-in. filters every 1–3 months, or follow the filter maker's guidance and your owner's manual.

Before you buy

Pull the old filter and read the size printed on its frame. Nominal sizes are rounded up: a 15.5 x 24.5 in. filter is sold as 16 x 25.

MERV notes

Your furnace manual lists the filter's dimensions, not its MERV rating. Higher-MERV filters restrict more air. Manufacturers such as Carrier recommend keeping the clean-filter pressure drop under 0.2 in. w.c. (ideally under 0.1). Lennox warns that an over-restrictive filter can trip the high limit in winter and freeze the coil in summer. If you want MERV 11–13, a 4-in. media cabinet is the usual route. Ask an HVAC tech to check static pressure. Nominal sizes are rounded: a filter labeled 16 x 25 x 1 actually measures about 15.5 x 24.5 x 0.75.

Related models

Where this data came from

Manufacturer document for Carrier 58TN0B / 58TN1B
Last checked 2026-10-29. Manufacturers revise documents. If your unit's label disagrees, trust the label.

Excerpt from the source

     *. Recommended to maintain air filter face velocity. See Product Data for part number.
      Table 7 – Air Filter Selection and Duct Sizing - In. (mm)                               AIR DUCTS
                                 FILTER SIZE                                                  General Requirements
  FURNACE
                            SIDE           BOTTOM                    FILTER TYPE*             The duct system should be designed and sized according to accepted
CASING WIDTH
                         RETURN            RETURN                                             national standards such as those published by: Air Conditioning
                        16 x 25 x 3/4    14 x 25 x 3/4                                        Contractors Association (ACCA), Sheet Metal and Air Conditioning
  14-3/16 (360)                                                         Washable
                      (406 x 635 x 19) (356 x 635 x 19)
                                                                                              Contractors National Association (SMACNA) or American Society of
                        16 x 25 x 3/4    16 x 25 x 3/4
   17-1/2 (445)                                                         Washable              Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) or
                      (406 x 635 x 19) (406 x 635 x 19)
                        16 x 25 x 3/4    20 x 25 x 3/4
                                                                                              consult The Air Systems Design Guidelines reference tables available
     21 (533)                                                           Washable              from your local distributor. The duct system should be sized to handle
                      (406 x 635 x 19) (508 x 635 x 19)
                        16 x 25 x 3/4    24 x 25 x 3/4                                        the required system design CFM at the design external static pressure.
   24-1/2 (622)                                                         Washable              The furnace airflow rates are provided in Table 13 thru Table 20 – Air
                      (406 x 635 x 19) (610 x 635 x 19)
                                                                                              Delivery-CFM. When a furnace is installed so that the supply ducts carry
     *. Recommended to maintain air filter face velocity. See Product Data Sheet
        for part number.                        

FAQ

What size filter does the Carrier 58TN0B / 58TN1B use?

Carrier 58TN0B / 58TN1B filter sizes: 14 x 25 x 3/4, 16 x 25 x 3/4, 20 x 25 x 3/4 and 24 x 25 x 3/4, as listed in the Carrier source document's filter table. Which size fits depends on your cabinet and return. This page is pending human review, so check the source excerpt below. 14 x 25 x 3/4; 16 x 25 x 3/4; 20 x 25 x 3/4; 24 x 25 x 3/4.

How often should I replace the Carrier 58TN0B / 58TN1B filter?

General guidance (not from this manual): check monthly and replace 1-in. filters every 1–3 months, or follow the filter maker's guidance and your owner's manual.

Why doesn't my filter measure exactly 16 x 25?

Filter sizes are nominal (rounded). A filter sold as 16 x 25 x 1 actually measures about 15.5 x 24.5 x 0.75 in. Buy by the nominal size printed on the frame.

How thick is the Carrier 58TN0B / 58TN1B filter?

Every size found in the source table is 3/4 in. thick: 14 x 25 x 3/4, 16 x 25 x 3/4, 20 x 25 x 3/4 and 24 x 25 x 3/4. Pending human review; check the excerpt.

Where does this information come from?

Manufacturer document for Carrier 58TN0B / 58TN1B (https://www.shareddocs.com/hvac/docs/1009/Public/0E/58TN0B-03SI.pdf), last checked 2026-10-29.