Bryant 987MC furnace: filter size

Our script found these filter sizes in the Bryant 987MC source document's filter table: 16x25x3/4, 20x25x3/4, 24x25x3/4. This page is pending human review, so check the source excerpt on the page to see which size applies to your cabinet and return.

Auto-extracted · review pending Filter sizes auto-extracted from the manufacturer document.

Filter sizes by cabinet / model

Sizes found in the source table
16 x 25 x 3/4
20 x 25 x 3/4
24 x 25 x 3/4

Extracted by script from the linked document. Read the excerpt to see which size applies to which cabinet or return.

Measuring a furnace air filter's edge with a tape measure
Illustration only. Not this manufacturer's part.

Replacement interval

General guidance (not from this manual): check monthly and replace 1-in. filters every 1–3 months, or follow the filter maker's guidance and your owner's manual.

Before you buy

Pull the old filter and read the size printed on its frame. Nominal sizes are rounded up: a 15.5 x 24.5 in. filter is sold as 16 x 25.

Buy

Match the size or part number printed on your current filter.

MERV notes

Your furnace manual lists the filter's dimensions, not its MERV rating. Higher-MERV filters restrict more air. Manufacturers such as Carrier recommend keeping the clean-filter pressure drop under 0.2 in. w.c. (ideally under 0.1). Lennox warns that an over-restrictive filter can trip the high limit in winter and freeze the coil in summer. If you want MERV 11–13, a 4-in. media cabinet is the usual route. Ask an HVAC tech to check static pressure. Nominal sizes are rounded: a filter labeled 16 x 25 x 1 actually measures about 15.5 x 24.5 x 0.75.

Where this data came from

Manufacturer document for Bryant 987MC
Last checked 2026-10-25. Manufacturers revise documents. If your unit's label disagrees, trust the label.

Excerpt from the source

The cooling coil must be installed parallel with, or on the downstream                             future upgrades to other IAQ devices.
side of the unit to avoid condensation in the heat exchangers. When
                                                                                                     FURNACE                          FILTER SIZE
installed parallel with the furnace, dampers or other flow control must
                                                                                                      CASING                 SIDE                    BOTTOM              FILTER TYPE
prevent chilled air from entering the furnace. If the dampers are                                     WIDTH                 RETURN                   RETURN
manually operated, they must be equipped with means to prevent                                                             16 x 25 x 3/4            16 x 25 x 3/4
operation of either unit unless the damper is in the full-heat or full-cool                          17-1/2 (445)
                                                                                                                         (406 x 635 x 19)         (406 x 635 x 19)          Washable*
position.                                                                                                                  16 x 25 x 3/4            20 x 25 x 3/4
                                                                                                       21 (533)
                                                                                                                         (406 x 635 x 19)         (508 x 635 x 19)          Washable*
                                                                                                                           16 x 25 x 3/4            24 x 25 x 3/4
                                                                                                     24-1/2 (622)        (406 x 635 x 19)         (610 x 635 x 19)          Washable*
                                                                                                        *. Recommended to maintain air filter face velocity. See Product Data for P/N.
                             Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
                                                                                         18
987MC: Installation, Start-up, Operating and Service an

FAQ

What size filter does the Bryant 987MC use?

Our script found these filter sizes in the Bryant 987MC source document's filter table: 16x25x3/4, 20x25x3/4, 24x25x3/4. This page is pending human review, so check the source excerpt on the page to see which size applies to your cabinet and return. 16 x 25 x 3/4; 20 x 25 x 3/4; 24 x 25 x 3/4.

How often should I replace the Bryant 987MC filter?

General guidance (not from this manual): check monthly and replace 1-in. filters every 1–3 months, or follow the filter maker's guidance and your owner's manual.

Why doesn't my filter measure exactly 16 x 25?

Filter sizes are nominal (rounded). A filter sold as 16 x 25 x 1 actually measures about 15.5 x 24.5 x 0.75 in. Buy by the nominal size printed on the frame.

Where does this information come from?

Manufacturer document for Bryant 987MC (https://www.shareddocs.com/hvac/docs/1009/Public/0C/II987MC-04.pdf), last checked 2026-10-25.