Home › Furnace filters › 810SB / 811SB

Bryant 810SB / 811SB furnace: filter size

Bryant 810SB / 811SB filter sizes: 14 x 25 x 3/4, 16 x 25 x 3/4, 20 x 25 x 3/4 and 24 x 25 x 3/4, as listed in the Bryant source document's filter table. Which size fits depends on your cabinet and return. This page is pending human review, so check the source excerpt below.

Auto-extracted · review pending Filter sizes auto-extracted from the manufacturer document.

Last checked against the manufacturer document:

Filter sizes by cabinet / model

Sizes found in the source table
14 x 25 x 3/4
16 x 25 x 3/4
20 x 25 x 3/4
24 x 25 x 3/4

Extracted by script from the linked document. Read the excerpt to see which size applies to which cabinet or return.

Measuring a furnace air filter's edge with a tape measure
Illustration only. Not this manufacturer's part.

Replacement interval

General guidance (not from this manual): check monthly and replace 1-in. filters every 1–3 months, or follow the filter maker's guidance and your owner's manual.

Before you buy

Pull the old filter and read the size printed on its frame. Nominal sizes are rounded up: a 15.5 x 24.5 in. filter is sold as 16 x 25.

MERV notes

Your furnace manual lists the filter's dimensions, not its MERV rating. Higher-MERV filters restrict more air. Manufacturers such as Carrier recommend keeping the clean-filter pressure drop under 0.2 in. w.c. (ideally under 0.1). Lennox warns that an over-restrictive filter can trip the high limit in winter and freeze the coil in summer. If you want MERV 11–13, a 4-in. media cabinet is the usual route. Ask an HVAC tech to check static pressure. Nominal sizes are rounded: a filter labeled 16 x 25 x 1 actually measures about 15.5 x 24.5 x 0.75.

Related models

Where this data came from

Manufacturer document for Bryant 810SB / 811SB
Last checked 2026-11-06. Manufacturers revise documents. If your unit's label disagrees, trust the label.

Excerpt from the source

HAZARD                                                                                    7. Replace filter cabinet door.
Failure to follow this warning could result in personal injury, death                     8. Turn on electrical supply to furnace.
and/or property damage.                                                                                Table 18 – Filter Size Information (In. / mm)
Never operate unit without a filter or with filter access door removed.                    FURNACE                FILTER SIZE (In. / mm)
                                                                                            CASING                                                      FILTER
                                                                                             WIDTH           Side Return         Bottom Return          TYPE*
                          ! CAUTION                                                         In. (mm)
                                                                                              14-1/2          16 x 25 x 3/4        14 x 25 x 3/4
                                                                                                                                                       Washable
CUT HAZARD                                                                                    (368)         (406 x 635 x 19)     (356 x 635 x 19)
Failure to follow this caution may result in personal injury.                                 17-1/2         16 X 25 X 3/4        16 X 25 X 3/4
                                                                                                                                                       Washable
Sheet metal parts may have sharp edges or burrs. Use care and wear                            (445)         (406 x 635 x 19)     (406 x 635 x 19)
appropriate protective clothing, safety glasses and gloves when                                 21            16 x 25 x 3/4       20 X 25 X 3/4
                                                                                                                                                       Washable
                                                                                              (533)         (406 x 635 x 19)     (508 x 635 x 19)
handling parts and servicing furnaces.
                                                                                                24            16 x 25 x 3/4       24 X 25 X 3/4
         

FAQ

What size filter does the Bryant 810SB / 811SB use?

Bryant 810SB / 811SB filter sizes: 14 x 25 x 3/4, 16 x 25 x 3/4, 20 x 25 x 3/4 and 24 x 25 x 3/4, as listed in the Bryant source document's filter table. Which size fits depends on your cabinet and return. This page is pending human review, so check the source excerpt below. 14 x 25 x 3/4; 16 x 25 x 3/4; 20 x 25 x 3/4; 24 x 25 x 3/4.

How often should I replace the Bryant 810SB / 811SB filter?

General guidance (not from this manual): check monthly and replace 1-in. filters every 1–3 months, or follow the filter maker's guidance and your owner's manual.

Why doesn't my filter measure exactly 16 x 25?

Filter sizes are nominal (rounded). A filter sold as 16 x 25 x 1 actually measures about 15.5 x 24.5 x 0.75 in. Buy by the nominal size printed on the frame.

How thick is the Bryant 810SB / 811SB filter?

Every size found in the source table is 3/4 in. thick: 14 x 25 x 3/4, 16 x 25 x 3/4, 20 x 25 x 3/4 and 24 x 25 x 3/4. Pending human review; check the excerpt.

Where does this information come from?

Manufacturer document for Bryant 810SB / 811SB (https://www.shareddocs.com/hvac/docs/1009/Public/09/II810SB-01.pdf), last checked 2026-11-06.