Bryant 313AAV / 313JAV furnace: filter size

Bryant 313AAV / 313JAV filter sizes: 14 x 25 x 3/4, 16 x 25 x 3/4, 20 x 25 x 3/4 and 24 x 25 x 3/4, as listed in the Bryant source document's filter table. Which size fits depends on your cabinet and return. This page is pending human review, so check the source excerpt below.

Auto-extracted · review pending Filter sizes auto-extracted from the manufacturer document.

Last checked against the manufacturer document:

Filter sizes by cabinet / model

Sizes found in the source table
14 x 25 x 3/4
16 x 25 x 3/4
20 x 25 x 3/4
24 x 25 x 3/4

Extracted by script from the linked document. Read the excerpt to see which size applies to which cabinet or return.

Close-up of a pleated furnace air filter
Illustration only. Not this manufacturer's part.

Replacement interval

General guidance (not from this manual): check monthly and replace 1-in. filters every 1–3 months, or follow the filter maker's guidance and your owner's manual.

Before you buy

Pull the old filter and read the size printed on its frame. Nominal sizes are rounded up: a 15.5 x 24.5 in. filter is sold as 16 x 25.

MERV notes

Your furnace manual lists the filter's dimensions, not its MERV rating. Higher-MERV filters restrict more air. Manufacturers such as Carrier recommend keeping the clean-filter pressure drop under 0.2 in. w.c. (ideally under 0.1). Lennox warns that an over-restrictive filter can trip the high limit in winter and freeze the coil in summer. If you want MERV 11–13, a 4-in. media cabinet is the usual route. Ask an HVAC tech to check static pressure. Nominal sizes are rounded: a filter labeled 16 x 25 x 1 actually measures about 15.5 x 24.5 x 0.75.

Related models

Where this data came from

Manufacturer document for Bryant 313AAV / 313JAV
Last checked 2026-11-03. Manufacturers revise documents. If your unit's label disagrees, trust the label.

Excerpt from the source

                                                                             6. Remove two screws holding blower assembly to blower
  FURNACE
                          FILTER SIZE (In. / mm)
                                                                                deck and slide blower assembly out of furnace.
   CASING
    WIDTH
                                                          FILTER TYPE        7. Clean blower wheel and motor using a vacuum with soft
   In. (mm)         Side Return        Bottom Return                            brush attachment. Blower wheel blades may be cleaned
   14 ---1/2         16 x 25 x 3/4       14 x 25 x 3/4                          with a small paint or flux brush. Do not remove or disturb
                                                           Washable*
    (368)          (406 x 635 x 19)    (356 x 635 x 19)                         balance weights (clips) on blower wheel blades.
                                                                                                                                                313AAV
   17 ---1/2        16 X 25 X 3/4       16 X 25 X 3/4                        8. Vacuum any loose dust from blower housing, wheel and
                                                           Washable*
    (445)          (406 x 635 x 19)    (406 x 635 x 19)
                                                                                motor.
                     16 x 25 x 3/4      20 X 25 X 3/4
   21 (533)                                                Washable*         9. If a greasy residue is present on blower wheel, remove
                   (406 x 635 x 19)    (508 x 635 x 19)
                     16 x 25 x 3/4      24 X 25 X 3/4                           wheel from the blower housing and wash it with an appro-
   24 (610)                                                Washable*
                   (406 x 635 x 19)    (610 x 635 x 19)                         priate degreaser. To remove wheel:

FAQ

What size filter does the Bryant 313AAV / 313JAV use?

Bryant 313AAV / 313JAV filter sizes: 14 x 25 x 3/4, 16 x 25 x 3/4, 20 x 25 x 3/4 and 24 x 25 x 3/4, as listed in the Bryant source document's filter table. Which size fits depends on your cabinet and return. This page is pending human review, so check the source excerpt below. 14 x 25 x 3/4; 16 x 25 x 3/4; 20 x 25 x 3/4; 24 x 25 x 3/4.

How often should I replace the Bryant 313AAV / 313JAV filter?

General guidance (not from this manual): check monthly and replace 1-in. filters every 1–3 months, or follow the filter maker's guidance and your owner's manual.

Why doesn't my filter measure exactly 16 x 25?

Filter sizes are nominal (rounded). A filter sold as 16 x 25 x 1 actually measures about 15.5 x 24.5 x 0.75 in. Buy by the nominal size printed on the frame.

How thick is the Bryant 313AAV / 313JAV filter?

Every size found in the source table is 3/4 in. thick: 14 x 25 x 3/4, 16 x 25 x 3/4, 20 x 25 x 3/4 and 24 x 25 x 3/4. Pending human review; check the excerpt.

Where does this information come from?

Manufacturer document for Bryant 313AAV / 313JAV (https://www.shareddocs.com/hvac/docs/1009/Public/03/II313AAV-06.pdf), last checked 2026-11-03.